Case Study: Efficient Energy use in preschool "VARPELIS" - Utena city, Lithuania

Case Study (90 KB PDF)

Summary

The main aspects of the project were in the year of 1998 to fulfil Energy Audit of preschool "VARPELIS" in Utena city, Republic of Lithuania; in the years of 1999-2001, according to results and proposals of Energy Audit analysis there was accomplished partial preschool's building renovation and full renovation of heating system; after building renovation in 2002 there was carried out an Energy Monitoring in order to measure and compare energy consumption, climate conditions before and after renovation of preschool's building. In summary the implemented projects has given an effect to satisfy Energy Audit recommendations by fostering and teaching kindergartners as well, as municipality administrative employees of rational and efficient energy use in public houses.

Recommendations of the projects could be identified as it may be of service to implement Energy Audit projects in public, industry or private buildings to ensure the energy efficiency, energy conservation and acceptable payback time of the projects.

The energy audit was financed from state budget. Renovation of the preschool's building financed from municipality budget and the energy monitoring was financed from state budget.

Results

Table 1: Renovation of heating system, walls, windows, doors and roof reconstructing it to curb roof.

Energy savedTotal heat energy saved - 123,4 MWh/year*
Energy produced by renewables-
Economic benefitsSavings per year - 5.182,17 EUR
Environmental benefitsreduction around 35,3 t of CO2
Jobs created-
Behavioral changes achieved  

*NOTE. Heat energy savings counted for normal year period.

Energy saving results of the projects are shown in the table below.

Table 2: Heat losses and savings counted before and after building renovation for normal year period.

MeansHeat lossesSavings after renovation
Before renovation After renovation
MWh/yearkWh/m²flMWh/yearkWh/m²fl MWh/year %
Windows and doors223.02148.15173.98113.6249.04 22.0
Walls76.8251.0418.6912.4258.1375.7
Roof28.4218.88 18.9912.629.4333.2
1st stage ceiling74.5249.5167.7545.026.779.1
TOTAL 402.8267.64279.4185.65123.430.6

NOTE. "m²fl" - per square meter of premises floor.

Keywords

To find similar reports, click on a keyword below:
Buildings : Heat/Heating : ManagEnergy : Refurbishment of Buildings : Schools & Colleges

Contacts

Complete the Questionnaire to add your organisation to this website

LITHUANIA

SC Energy Agency, Lithuania

Last Modified 16/07/2008 - The information on this site is subject to a Disclaimer and Copyright Notice